Dec 14 2022
There doesn't seem to be anything mechanically wrong with the toy, although the motor and gearbox don't seem to be accessible without breaking something.
Dec 13 2022
Dec 5 2022
The capacitors on both boards arrived pretty banged up.
Dec 3 2022
String Shelf
Turny Thing
Motor Drivers
Dec 1 2022
Nov 22 2022
Nov 4 2022
Couple of years ago the furnace wasn't working so well. Light comes on, three reds. Pressure switch stuck open. I take off a panel, pull the pressure switches. The contacts close properly. No clue what's wrong. Call an HVAC guy. He's pretty busy. No problem, we got plenty of sweaters. Ha. He makes it out early the next week.
... condensate drain ...
...there's enough absorbent material underneath the sink...
Nov 3 2022
I can't see a way to make the trap be any less garbage than it is because the 4" flanged tailpipe (the shortest flanged 1-1/4" tailpipe I could find) plus an additional 8" of tailpipe underneath it (the only 1-1/4" branch tailpipe I could find, which is only available with a slip fitting) means that the bottom of the lower tailpipe is super low. It looks like I left an extra 6" of flexible pipe on the drain side for fun, but that's just the rigid bottom of the tailpipe plus the minimum bend radius without making the flexible pipe start to crimp -- the bottom of the tailpipe is like 1-1/2" below the black plastic retainer clip.
Since there's no fresh water supply to the dehumidifier I don't think there's much benefit to an air gap, as there's no way backflow could ever contaminate a supply line. A clogged sink drain could possibly drain sink water out through the dehumidifier bucket, but the top of the drain line is only ~1"-2" below the top of the sink so it would overflow the basin onto the floor before very long anyway.
Oct 26 2022
Other options I explored and rejected:
- Inline Comments: See PHI2217. See PHI2206. Inline comments don't currently attach images.
- Destroying Edges: See PHI2201. See PHI2217. Destroying files that have old edge types may raise warnings. The destruction still works, although it doesn't hit the edges.
- Destroying Files: See PHI2217. Destroying an object doesn't destroy corresponding FileAttachment objects, so you can end up with ghosts in the UI.
There are some remaining non-security bugs with this that I'll follow up on in T13682. I believe the security side of this is now resolved.
The details of this attack will be disclosed at a later date, once installs have had some sort of plausible chance to upgrade.
An earlier patch here (rCORE6d6170f76463) swapped binlogs to MIXED and set a 24-hour retention policy. This issue has not reoccurred in the cluster since that patch went out, but the root causes remain unresolved.
I filed T13687 as a followup for preventing this particular sort of error (where a Phobject is incorrectly serialized directly).
I patched and partially deployed this in early August. Another unattended MySQL upgrade went out on Monday night, also didn't restart MySQL on affected hosts, and caused some downtime on hosts that didn't have the patch (to "disable unattended upgrades"). I've now deployed this everywhere, and am presuming this is fixed until evidence arises to the contrary.
Oct 25 2022
Aug 8 2022
Feature | Dimension |
---|---|
Barrel | 6.8mm |
Divot Size | 2.5mm H x 1.15mm W x 1.6mm D |
Divot Distance | 7mm |
Shaft | ~3mm |
Jul 29 2022
Jul 8 2022
That's very likely the same problem, and I think it should be fixed by updating to the current stable (rPf2a7db1 or newer).
Jun 14 2022
...ideally this sort of thing should fail loudly at serialization time...
Jun 13 2022
- The drydock_resource table could use a (status, ...) key to satisfy common/default queries.
Jun 7 2022
Jun 3 2022
May 31 2022
May 28 2022
May 27 2022
May 26 2022
- Update some file/class names.
After recent changes, only DifferentialRevision and ManiphestTask still have onboard mail keys.