Page MenuHomePhabricator

Skip Conduit call log writes in read-only mode, allowing "conduit.ping" to run
ClosedPublic

Authored by epriestley on Jul 18 2017, 3:51 PM.
Tags
None
Referenced Files
F13104910: D18233.diff
Sat, Apr 27, 1:36 PM
Unknown Object (File)
Thu, Apr 25, 6:26 PM
Unknown Object (File)
Thu, Apr 25, 6:26 PM
Unknown Object (File)
Thu, Apr 25, 6:26 PM
Unknown Object (File)
Sat, Apr 20, 7:49 PM
Unknown Object (File)
Mon, Apr 1, 3:03 PM
Unknown Object (File)
Fri, Mar 29, 1:49 PM
Unknown Object (File)
Mar 27 2024, 8:15 PM
Subscribers
None

Details

Summary

Ref T10769. See PHI8. We have an unconditional logging write which we can skip in read-only mode.

Test Plan
  • Put Phabricator in read-only mode with cluster.read-only.
  • Called conduit.ping via web UI.
    • Before: write-on-read-only exception.
    • After: good result.

Diff Detail

Repository
rP Phabricator
Lint
Lint Not Applicable
Unit
Tests Not Applicable