Summary

Fixes T7721. Looks like this got renamed at some point but skipped. Also, change the true / false idx look ups to correct integers here since there's a warning in the error logs in this case without it.

Test Plan

made new user. loaded up conpherence and it worked. tried all the links too for good measure and they worked

Diff Detail

Repository
rP Phabricator
Lint
Lint Not Applicable
Unit
Tests Not Applicable

Event Timeline

btrahan retitled this revision from to Conpherence - fix fatal if you don't have conpherences.
btrahan updated this object.
btrahan edited the test plan for this revision. (Show Details)
btrahan added a reviewer: epriestley.
epriestley edited edge metadata.
This revision is now accepted and ready to land.Apr 1 2015, 2:59 PM